230VAC Efficiency, Power loss, PFC

With higher input voltage is the efficiency increases as well. We have measured a very nice 83.33% efficiency at just 40% load. In total we had more than 80% efficiency from 20 to 90% load which is a very good result from the OP650. This power supply will always provide good results in PCs with more than 130 watts constant load when connected to 230VAC power.



The loss of power is not that large as a result of the high efficiency at 230VAC. The upper line marks the power input and the lower line marks the output. The space in between is the power which has been lost during the work.



Again, we tested the standby power draw of the Silverstone supply, this time with 230VAC. With 230VAC the OP650 is using 1.7 watts of energy while doing "nothing" which is a slightly higher result than what we saw when connected to a 115VAC power grid. If you leave the PC off for a longer time you should always hit the switch or even unplug the cable. This not only saves you money, but could potentially help save wear and tear due to power surges, especially in areas with unreliable power.

The standby-efficiency was again tested with the loads of 0.1, 0.5 and 3.0 Ampere on the 5VSB rail while the power supply is not running. We see that the efficiency is slightly lower with 230VAC than with 115VAC. At 3 Ampere loading it is the same like with 115VAC.


The power factor correction with 230VAC was at an average level and working fine.



230VAC 12V Rail Tests Temperatures
Comments Locked

46 Comments

View All Comments

  • YellowWing - Friday, July 13, 2007 - link

    In a prior article you showed us the box you use for testing power supplies. I don't remember reading how the heat generated by the power supplies is removed from the sealed box. Does the temp of the air in the box rise with time? Would the drop off in voltage be less with full ventilation?
  • YellowWing - Friday, July 13, 2007 - link

    Brownouts have caused power supply failures for me in the past. How about dialing the input voltage down to 90 or so and see what happens.

    From experience I can say that some supplies don't survive at lower input voltages.
  • DerekWilson - Friday, July 13, 2007 - link

    we are considering looking at 90V input. Thanks for the suggestion.
  • bpt8056 - Friday, July 13, 2007 - link

    I just want to say that I thought AT did a great job on the review. Keep up the great work!
  • puffpio - Friday, July 13, 2007 - link

    Great article..looking forward to many many more

    On one of the graphs of the 230V tests, it is labeled as 115V
  • jonnyGURU - Friday, July 13, 2007 - link

    Good job. Clearly a lot of effort was put behind putting the methodology and this review together.

    Couple questions..

    1. How much of the voltage drop shown would you contribute to the resistance created by the interface board and wires located between the end of the PSU's connector and the actual load. This isn't my favorite power supply, but I know the voltage regulation isn't nearly as bad as you have it graphed. And naturallly, since load also creates resistance, your voltage is going to decrease exponentially if you're not loading and measuring at the end of the connector. Since you're using a Chroma, I know you're not loading and measuring at the connector. Perhaps you could rig a DMM to measure voltages at the end of the connector instead of reporting what the Chroma is telling you since the Chroma is going to be incorrect since it doesn't take into consideration this added resistance.

    2. Do you think it's possible to define "10%, 20%, etc." as it pertains to your loads. Naturally, you can't load all rails by 80%, 90%, 100%" because you'd easily exceed the power supplies capabilities. And certainly you're not loading the +12V with 80%, 90% 100% and then filling up the remainder with a 3.3V and 5V load because then you would crossload the PSU with an unusually high +12V load.

    3. And, at risk of sounding like I'm beating a dead horse, ripple and noise results. We all know spec is 1%, and ripple and noise does typically increase with load. It would be nice to see if the power supplies being tested stay within that spec. through out it's total advertised capability.

    Thanks and I look forward to the next PSU review!
  • mcvan - Saturday, July 14, 2007 - link

    Like Johnny said. ;)

    Another issue pertinent to the extreme sag in voltage lines and perhaps to the soaring temperatures is to ask how long the PSU was run at each load level (and in total) and what was the air temperature at the PSU intake? Maybe the test box is just letting the PSU get way too unnaturally hot, and this has a deleterious effect on performance. This test box is not the same as thermal control chamber where you can dial in a specific target temperature, which will then be held constant by the chamber throughout the testing.

    Since the test box is well insulated and sealed, there is a direct correlation between time spent with the PSU on and internal air temperature. No matter how the PSU is cooled, at any load, the temperature of the test box should rise continuously (even if only incrementally at very low load) as long as the PSU is running. This is a significant uncontrolled and unreported factor. That PSU intake temperature will be dictated by a complex mix of factors, by too many variables --

    -starting ambient air temp in the box
    -how long the PSU is kept running in the box and at which loads
    -heat loss out of the box
    -efficiency curve of the PSU
    -fan and fan controller characteristics

    If the time spent at each load and the starting ambient temp is kept the same for each and all PSUs, then the variables are correctly contained to the PSUs being tested. Then differences in the air temperature at the intake at any given power level for each PSU would reflect real differences in the cooling system and efficiency of each PSU. It would ensure a more level thermal playing field.
  • qpwoei - Friday, July 13, 2007 - link

    quote:

    And, at risk of sounding like I'm beating a dead horse


    While we're beating dead horses, I'll land a few blows on the dynamic load response horse as well :)
  • SilthDraeth - Friday, July 13, 2007 - link

    Seems like you know what you are talking about. I hope they take some of your points into consideration, since they all seem very valid.
  • jonnyGURU - Friday, July 13, 2007 - link

    Thanks. But I'm just an old hack. ;)